본문 바로가기

Diaphragm

P790 Series_Diaphragm seal for Pressure Instrument

P790 Series (P791, P792)

Service intended

P790 series diaphragm seal are suitable for conditions where the process medium can cause corrosion to the instrument connection and the pressure sensing element, which the process medium contains suspended solid particles are viscous and be clossed. It is also suitable for where the process medium can freeze or solidify the internal parts of the instrument and where the medium requires flushing from the system to prevent contamination.

Design Instrument welded diaphragm with threaded process connection, require hydraulic fluid to transmitter pressure to instrument.
Filling liquid Silicone oil
Working temperature Ambient : -20 ~ 65 °C
Fluid : Refer to filling liquid reference table
Diaphragm material Diaphragms are available in many corrosion resistant materials. Compatibility of selected material and process fluid should be determined by the user
Temperature effect Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately
±0.5 % per 10 ℃ of full scale

Standard features

Upper flange (Gauge side) Stainless steel (304, 316), Titanium, Monel
Diaphragm material Stainless steel(316L) Hastelloy C-276, Titanium, Tantalum, Monel
Pressure connection Thread type : PT, PF, and NPT others feasible
Flange type : ANSI(ASME), JIS or other standard
Capillary Capillary : Ø3.0 mm, 316L
Flexible tube : Ø7.5 mm, 304, PVC coated
Note PTFE lining is available up to 7 MPa (Coating)

© WISE Control Inc. All rights reserved. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.